{"id":2472679473232,"title":"Invacare MicroAIR MA65 Alternating Pressure Mattress","handle":"invacare-microair-ma65-alternating-pressure-mattress","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/files\/Need_Help_Choosing_Bed_080919_large.jpg?v=1565964440\" alt=\"Expert Help\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n[TABS]\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eThe Invacare® microAIR® MA65 provides a temperate climate for patients with its ability to circulate air within the mattress. This alternating pressure mattress has 20 horizontally configured bladders. Product will not bottom out with mattress hose attached to the compressor power unit. Alternating pressure therapeutics support system with on demand low air loss, 50 LPM compressor, automatic pressure monitoring and automatic wireless fowler.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Risk to Stage II\u003c\/strong\u003e (Prevention and Ulcer Treatment): Ideal for High Risk Ulcer Prevention and for treatment of patients who already have Stage II skin breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eState of the art compressor\u003c\/strong\u003e – With solenoid valve system allows for easy set up and effective therapy cyclesFour therapy times – Can be adjusted for patient comfort to provide pressure relief\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternating Pressure:\u003c\/strong\u003e Reduces interface pressure to aid in the prevention and treatment of pressure ulcers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Demand Low Air Loss:\u003c\/strong\u003e Air is sent inside the mattress to keep the mattress environment cool ad assist with moisture management and maintain a dryer environment. The On Demand Low Air Loss pushes air in between the bladders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternating Pressure Therapy Time Cycles:\u003c\/strong\u003e Cycles of 5, 10, 15, 20 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 Air Cells:\u003c\/strong\u003e Made from 70 Denier urethane coated nylon. Easy connect and disconnect with quick connect elbows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew wireless fowler technology\u003c\/strong\u003e, real time pressure monitoring and energy conserving power units combine to make microAIR surfaces the most efficient dynamic support surfaces in the market. Within the power units is a pressure transducer that maintains surface pressure not to exceed 32mm\/Hg.  The solenoid valve within the compressor opens and closes the air valve automatically to maintain the pressure relief range prescribed.  The compressor turns off to save energy when the patient is in the range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Fowler Technology\u003c\/strong\u003e is an innovation exclusive that assures patient comfort. From time to time patients need to sit up in bed, which creates the problem of additional pressure in the coccyx area and possible disruption of treatment. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking in sync with the power unit\u003c\/strong\u003e, the transmitter installed in the head section of the mattress signals the power unit when the head portion begins to raise. The power unit immediately begins adding 25% more air to the mattress to prevent patient contact with a hard surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Foam Mat:\u003c\/strong\u003e Added safety feature to prevent patient from bottoming out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant Pressure Monitoring:\u003c\/strong\u003e Sensor techonology constantly adjusts the pressure to regulate the air inside the mattress and maintain the pressure at or below 32mm\/Hg to avoid capillary occlusion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Fowler:\u003c\/strong\u003e 25% more air is added into the mattress, preventing the patient from bottoming out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and Visual Alarms:\u003c\/strong\u003e Warns patient and caregiver of low pressure and power outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Lock Out Button:\u003c\/strong\u003e Prevents tampering or accidental adjustments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Outage Safety:\u003c\/strong\u003e Mattress remains inflated as long as the air hose remains connected to the compressor. System returns to pre-power outage settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMattress Cover:\u003c\/strong\u003e Anti-microbial, fluid-proof, vapor permeable, guards against friction and shear. 70 Denier quilted nylon with 1000 denier nylon bottom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e 50 LPM compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003ePrevention and Ulcer Treatment:\u003c\/strong\u003e Prevention \/ Treatment and Management of Pressure Ulcers\u003cbr\u003e\u003cstrong\u003eAlternating Pressure:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eLow Air Loss:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eMattress Size:\u003c\/strong\u003e 36\", 42\" or 48\" x 80\" x 10\"\u003cbr\u003e\u003cstrong\u003eMattress Cover:\u003c\/strong\u003e Quilted 70 denier nylon with Anti-microbial, fluid-proof, vapor permeable \u003cbr\u003e\u003cstrong\u003eWeight Capacity:\u003c\/strong\u003e 350 lbs \/ 42\" and 48\" 1000lbs\u003cbr\u003e\u003cstrong\u003eCycle Times:\u003c\/strong\u003e 5, 10, 15, 20 minutes\u003cbr\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cbr\u003eMattress 1 Year\u003cbr\u003eMotor 2 Years\u003cbr\u003eCover 1 Year\u003c\/p\u003e\n\u003cp\u003e[\/TABS]\u003c\/p\u003e","published_at":"2020-03-26T10:30:23-05:00","created_at":"2019-02-20T18:41:45-06:00","vendor":"Invacare","type":"Hospital Mattress","tags":["Alternating Pressure Mattress","Bariatric Mattress","Hospital-Mattresses_Alternating Pressure Mattresses","Hospital-Mattresses_Bariatric Mattresses","Hospital-Mattresses_Low Air Loss Mattresses","Low Air Loss Mattress"],"price":239900,"price_min":239900,"price_max":239900,"available":true,"price_varies":false,"compare_at_price":300000,"compare_at_price_min":300000,"compare_at_price_max":300000,"compare_at_price_varies":false,"variants":[{"id":21527067885648,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Invacare MicroAIR MA65 Alternating Pressure Mattress","public_title":null,"options":["Default Title"],"price":239900,"weight":0,"compare_at_price":300000,"inventory_management":null,"barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/MA65_B7_H.jpg?v=1572361775","\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65box.jpg?v=1572361775","\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65.jpg?v=1572361775","\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/quilted_cover_2_400_18835.1359799731.1280.1280_89921.1455776664.1280.1280__94037.1456770698.1280.1280_07451dad-433c-4805-b3a7-1d52d9971c41.jpg?v=1572361775"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/MA65_B7_H.jpg?v=1572361775","options":["Title"],"media":[{"alt":"Invacare MicroAIR MA65 Alternating Pressure Mattress - Express Hospital Beds","id":1944382701648,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2000,"width":2000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/MA65_B7_H.jpg?v=1569381141"},"aspect_ratio":1.0,"height":2000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/MA65_B7_H.jpg?v=1569381141","width":2000},{"alt":"Invacare MicroAIR MA65 Alternating Pressure Mattress - Express Hospital Beds","id":1944382734416,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1042,"width":1042,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65box.jpg?v=1569381141"},"aspect_ratio":1.0,"height":1042,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65box.jpg?v=1569381141","width":1042},{"alt":"Invacare MicroAIR MA65 Alternating Pressure Mattress - Express Hospital Beds","id":1944382767184,"position":3,"preview_image":{"aspect_ratio":1.149,"height":1649,"width":1894,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65.jpg?v=1569381141"},"aspect_ratio":1.149,"height":1649,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/ma65.jpg?v=1569381141","width":1894},{"alt":"Invacare MicroAIR MA65 Alternating Pressure Mattress - Express Hospital Beds","id":1944382832720,"position":4,"preview_image":{"aspect_ratio":1.0,"height":450,"width":450,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/quilted_cover_2_400_18835.1359799731.1280.1280_89921.1455776664.1280.1280__94037.1456770698.1280.1280_07451dad-433c-4805-b3a7-1d52d9971c41.jpg?v=1569381141"},"aspect_ratio":1.0,"height":450,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/products\/quilted_cover_2_400_18835.1359799731.1280.1280_89921.1455776664.1280.1280__94037.1456770698.1280.1280_07451dad-433c-4805-b3a7-1d52d9971c41.jpg?v=1569381141","width":450}],"content":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0082\/7863\/8672\/files\/Need_Help_Choosing_Bed_080919_large.jpg?v=1565964440\" alt=\"Expert Help\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n[TABS]\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eThe Invacare® microAIR® MA65 provides a temperate climate for patients with its ability to circulate air within the mattress. This alternating pressure mattress has 20 horizontally configured bladders. Product will not bottom out with mattress hose attached to the compressor power unit. Alternating pressure therapeutics support system with on demand low air loss, 50 LPM compressor, automatic pressure monitoring and automatic wireless fowler.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Risk to Stage II\u003c\/strong\u003e (Prevention and Ulcer Treatment): Ideal for High Risk Ulcer Prevention and for treatment of patients who already have Stage II skin breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eState of the art compressor\u003c\/strong\u003e – With solenoid valve system allows for easy set up and effective therapy cyclesFour therapy times – Can be adjusted for patient comfort to provide pressure relief\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternating Pressure:\u003c\/strong\u003e Reduces interface pressure to aid in the prevention and treatment of pressure ulcers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Demand Low Air Loss:\u003c\/strong\u003e Air is sent inside the mattress to keep the mattress environment cool ad assist with moisture management and maintain a dryer environment. The On Demand Low Air Loss pushes air in between the bladders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternating Pressure Therapy Time Cycles:\u003c\/strong\u003e Cycles of 5, 10, 15, 20 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 Air Cells:\u003c\/strong\u003e Made from 70 Denier urethane coated nylon. Easy connect and disconnect with quick connect elbows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew wireless fowler technology\u003c\/strong\u003e, real time pressure monitoring and energy conserving power units combine to make microAIR surfaces the most efficient dynamic support surfaces in the market. Within the power units is a pressure transducer that maintains surface pressure not to exceed 32mm\/Hg.  The solenoid valve within the compressor opens and closes the air valve automatically to maintain the pressure relief range prescribed.  The compressor turns off to save energy when the patient is in the range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Fowler Technology\u003c\/strong\u003e is an innovation exclusive that assures patient comfort. From time to time patients need to sit up in bed, which creates the problem of additional pressure in the coccyx area and possible disruption of treatment. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking in sync with the power unit\u003c\/strong\u003e, the transmitter installed in the head section of the mattress signals the power unit when the head portion begins to raise. The power unit immediately begins adding 25% more air to the mattress to prevent patient contact with a hard surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Foam Mat:\u003c\/strong\u003e Added safety feature to prevent patient from bottoming out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant Pressure Monitoring:\u003c\/strong\u003e Sensor techonology constantly adjusts the pressure to regulate the air inside the mattress and maintain the pressure at or below 32mm\/Hg to avoid capillary occlusion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Fowler:\u003c\/strong\u003e 25% more air is added into the mattress, preventing the patient from bottoming out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and Visual Alarms:\u003c\/strong\u003e Warns patient and caregiver of low pressure and power outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Lock Out Button:\u003c\/strong\u003e Prevents tampering or accidental adjustments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Outage Safety:\u003c\/strong\u003e Mattress remains inflated as long as the air hose remains connected to the compressor. System returns to pre-power outage settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMattress Cover:\u003c\/strong\u003e Anti-microbial, fluid-proof, vapor permeable, guards against friction and shear. 70 Denier quilted nylon with 1000 denier nylon bottom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e 50 LPM compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003ePrevention and Ulcer Treatment:\u003c\/strong\u003e Prevention \/ Treatment and Management of Pressure Ulcers\u003cbr\u003e\u003cstrong\u003eAlternating Pressure:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eLow Air Loss:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eMattress Size:\u003c\/strong\u003e 36\", 42\" or 48\" x 80\" x 10\"\u003cbr\u003e\u003cstrong\u003eMattress Cover:\u003c\/strong\u003e Quilted 70 denier nylon with Anti-microbial, fluid-proof, vapor permeable \u003cbr\u003e\u003cstrong\u003eWeight Capacity:\u003c\/strong\u003e 350 lbs \/ 42\" and 48\" 1000lbs\u003cbr\u003e\u003cstrong\u003eCycle Times:\u003c\/strong\u003e 5, 10, 15, 20 minutes\u003cbr\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cbr\u003eMattress 1 Year\u003cbr\u003eMotor 2 Years\u003cbr\u003eCover 1 Year\u003c\/p\u003e\n\u003cp\u003e[\/TABS]\u003c\/p\u003e"}

Invacare MicroAIR MA65 Alternating Pressure Mattress

$3,000.00
Maximum quantity available reached.


Expert Help
Sku:
Vendor: Invacare

The Invacare® microAIR® MA65 provides a temperate climate for patients with its ability to circulate air within the mattress. This alternating pressure mattress has 20 horizontally configured bladders. Product will not bottom out with mattress hose attached to the compressor power unit. Alternating pressure therapeutics support system with on demand low air loss, 50 LPM compressor, automatic pressure monitoring and automatic wireless fowler.

  • High Risk to Stage II (Prevention and Ulcer Treatment): Ideal for High Risk Ulcer Prevention and for treatment of patients who already have Stage II skin breakdown.
  • State of the art compressor – With solenoid valve system allows for easy set up and effective therapy cyclesFour therapy times – Can be adjusted for patient comfort to provide pressure relief
  • Alternating Pressure: Reduces interface pressure to aid in the prevention and treatment of pressure ulcers.
  • On Demand Low Air Loss: Air is sent inside the mattress to keep the mattress environment cool ad assist with moisture management and maintain a dryer environment. The On Demand Low Air Loss pushes air in between the bladders.
  • Alternating Pressure Therapy Time Cycles: Cycles of 5, 10, 15, 20 minutes
  • 20 Air Cells: Made from 70 Denier urethane coated nylon. Easy connect and disconnect with quick connect elbows.
  • New wireless fowler technology, real time pressure monitoring and energy conserving power units combine to make microAIR surfaces the most efficient dynamic support surfaces in the market. Within the power units is a pressure transducer that maintains surface pressure not to exceed 32mm/Hg.  The solenoid valve within the compressor opens and closes the air valve automatically to maintain the pressure relief range prescribed.  The compressor turns off to save energy when the patient is in the range.
  • Wireless Fowler Technology is an innovation exclusive that assures patient comfort. From time to time patients need to sit up in bed, which creates the problem of additional pressure in the coccyx area and possible disruption of treatment. 
  • Working in sync with the power unit, the transmitter installed in the head section of the mattress signals the power unit when the head portion begins to raise. The power unit immediately begins adding 25% more air to the mattress to prevent patient contact with a hard surface.
  • Safety Foam Mat: Added safety feature to prevent patient from bottoming out.
  • Constant Pressure Monitoring: Sensor techonology constantly adjusts the pressure to regulate the air inside the mattress and maintain the pressure at or below 32mm/Hg to avoid capillary occlusion.
  • Manual Fowler: 25% more air is added into the mattress, preventing the patient from bottoming out.
  • Audio and Visual Alarms: Warns patient and caregiver of low pressure and power outage.
  • System Lock Out Button: Prevents tampering or accidental adjustments
  • Power Outage Safety: Mattress remains inflated as long as the air hose remains connected to the compressor. System returns to pre-power outage settings.
  • Mattress Cover: Anti-microbial, fluid-proof, vapor permeable, guards against friction and shear. 70 Denier quilted nylon with 1000 denier nylon bottom.
  • Compressor: 50 LPM compressor

            Prevention and Ulcer Treatment: Prevention / Treatment and Management of Pressure Ulcers
            Alternating Pressure: Yes
            Low Air Loss: Yes
            Mattress Size: 36", 42" or 48" x 80" x 10"
            Mattress Cover: Quilted 70 denier nylon with Anti-microbial, fluid-proof, vapor permeable
            Weight Capacity: 350 lbs / 42" and 48" 1000lbs
            Cycle Times: 5, 10, 15, 20 minutes